The AC charging station provides a 220V single phase AC 50Hz, power supply for charging electric vehicles with on-board chargers. It is mainly suitable for the following places:
Large, medium and small electric vehicle charging stations;
Urban residential areas, shopping squares, electric power business places and other public places with electric vehicle parking spaces;
Motorway service area, station wharf and other transportation hub areas;
Real estate and project construction acceptance needs.
Integrated AC Charging Station (Metal Socket Type)
Model
Commercial Use
AF-AC-22-Y-B-O-1/2/3/4/5/6-JA-P
AF-AC-44-Y-B-O-1/2/3/4/5/6-JA-P
Specification
Rated Power
22 kW
44 kW
Charging Device
Installation Method
Floor standing mounted
Route
Bottom in and bottom out
Equipment Dimension
300×150×1400 mm
Weight
35 kg
Cable Length
5 m
Electrical Indicators
Input Voltage
AC 380V±15%
Input Frequency
50/60 Hz
Output Voltage
AC 380V±15%
Output Current
Type2: 16A/3P + 16A/3P
Type2: 32A/3P + 32A/3P
Current Limit Protection Value
≥110%
Metering Accuracy
Level 1
DLB
Support
RCD
Type A 30mA + 6mA DC
Functional Design
HMI
5-inch high-brightness color touch LCD + LED indicator strip
Charging Mode
Automatic full charge / Fixed energy / Fixed amount / Fixed time
Charging Methods
NFC (Swipe to charge), scan QR code to charge, App (optional)
Authentication and Payment Methods
Free Charge, RFID, App, NFC, Plug&Charge (ISO 15188) and Auto Charge (DIN 70121)
Network Interface
Ethernet, 4G, RS485, Wi-Fi (option)
Safety Design
Operative Norm
GB/T18487.1-2015; GB/T18487.2-2017; NB/T33002-2018; NB/T 33008.2-2018; GB/T34657.1-2017; EN IEC 62196-2:2016; EN IEC 61851-1:2019; EN 61851-23:2014; EN IEC 61851-21-2:2021; EN IEC 61000-6-1:2019; TÜV (DIN SPEC 70121/12.14, DIN SPEC 70122/11.18)
Check the packing box for the following items before installation (subject to the packing list)
Floor standing mounted type AC charging station(1 set )
Installation instructions (1 set)
1 piece of certificate of quality
Mounting expansion screws (4 pieces)
Key (2 pieces)
Installation Environment Requirements
The Ingress Protection of this series EV AC charging station: IP54;
Ambient temperature -20℃to +50℃;
Installation Method
Floor Standing Mounted Type Installation Method
Common Malfunctions
Troubleshooting / Method of Exclusion
When the connector is inserted, the interface does not show a connection or the message “Please start charging by swiping your card.”
Verify the connector is fully inserted and the lock is engaged. Ensure a secure connection between the connector and the vehicle.
After swiping the card to start charging, the session stops by itself after a while.
This is usually a communication issue. Note any error message, try another connector, and if it persists report it to the manufacturer.
Connector remains locked after charging (locking issue).
Complete settlement using the same card that started the session. If it remains locked, use that terminal to unlock after settlement or contact service.
“Jumping gun” (intermittent disconnection) during charging.
Ensure the IC card has sufficient balance before starting. If balance becomes insufficient during charging, the session will terminate automatically.
After charging, the connector is locked and cannot be removed.
Try starting a short charging cycle and then stop to trigger release. If it still won’t unplug, contact the manufacturer for maintenance.
Ammeter does not display current after starting charge.
Check the meter wiring for reversed phase/neutral or other miswiring and correct it if necessary.
Display does not light up after power on.
If LEDs show power but the display remains blank, replace the display module.
Grounding abnormality / not grounded.
Verify proper grounding. With correct earth connection: (1) when the connector is absent the 12V auxiliary indicator should be blue; (2) when inserted the 6V auxiliary indicator should be green.
Maintenance And Preservation Of EV AC Charging Station
Should charge station to do a good shade and rain prevention measures, outdoor recommended installation of shelter.
Check regularly whether all bolts in the charging stationary fastened, whether the connection line is loose, and the connection is not firm. Check for short circuit.
Pay attention to lightning protection to ensure effective shielding and reliable grounding of charging station
In use, the output voltage and current of the charging stationary controlled within the nominal range as far as possible to ensure that the charging station works in the state of maximum efficiency.
When the body stops using, stop charging output, then wrap the cable and put it back in place.
Note: in the process of charging station transportation, the charging station is packed firmly and the loading and unloading direction is marked. It is forbidden to store and transport the charging station upside down. There should be corresponding fastening measures to avoid strong vibration and turbulence to damage the outer packaging of the equipment.
Note: Non-professional personnel are strictly prohibited from installing the EV AC charger.